DC-DC Isolated Power Module 24V to 5V 12V 24V 2W Short Circuit Protection

    product detail

    ●Ultra-miniature standard package SIP package and standard pins

    ●Constant voltage input (10% Vin), isolated unregulated single output, 2W

    ●Low standby power consumption, input and output isolation withstand voltage 1 500VDC

    ●Low ripple noise (20MH bandwidth)<100mVp-p

    ●High efficiency, conversion efficiency can reach 90% (Typ.)

    ●Operating temperature range: -40°C~+85°C

    ●Good output short-circuit and over-current protection and self-recovery,

    ●High reliability, long life design, MTBF≥3500000H

    ●It is potted with high-quality waterproof and thermally conductive adhesive, which is dust-proof, moisture-proof, shock-proof and flame-retardant

    ●Comply with UL/CE/EMC and safety test requirements

    ●Can be used in medical, industrial control, electric power, instrumentation, communication, railway and other fields


    Operating temperature: -40~+85°C

    Storage temperature: -40~+125°C

    Relative humidity: 5~95%RH

    Cooling method: natural cooling

    Atmospheric pressure: 80~160Kpa

    Altitude:≤2000m

    Vibration: Vibration coefficient 10-55Hz, 10G, 30 Min.along X, Y and Z


    Input characteristics (room temperature test)

    Rated input voltage: 24VDC nominal input series

    Input voltage range: 21.6~26.4VDC

    Maximum input current: ≤0.1A

    Reflected ripple current: 15mA

    Impulse voltage (lsec.max) :≤30VDC

    Start voltage: 21.6VDC

    Input Filter Type: Capacitive Filter

    Hot plug: not supported

    Output Characteristics (Public)

    Output load (load percentage): 10%-100%

    Output voltage accuracy: ±15.0%(MAX)

    Linear adjustment rate: (input voltage ±1%) ±1.2% (other outputs)

    Load regulation rate: (10%~100% load)

    Output ripple and noise (mVp-p): ≤ 100mVp-p

    Temperature drift coefficient (full load): ±0.03%/°C

    Output short circuit protection: support