High-precision digital temperature and humidity controller module constant temperature and humidity control board/heating and refrigeration/dual output -68988
product detail
XY-TR01Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel
Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor.
Product Function:
Product features are two main types of classification: the functions of temperature and humidity;
Function of temperature are as follows:
-
The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode'C'.
Start temperature < stop temperature, heating mode 'H'.
-
Cooling mode:
When the temperature≥Start temperature,relay conduction,red led on, refrigeration equipment begin to work;
When the temperature≤Stop temperature,relay disconnect, red led off, refrigeration equipment stop to work;
-
Heating mode:
When the temperature≤Start temperature,relay conduction, red led on, heating equipment begin to work;
When the temperature≥Stop temperature,relay disconnect, red led off, heating equipment stop to work;
-
Temperature correction function OFE (-10.0 ~ 10℃):
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature:
1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface,can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;
The humidity function is as follows:
-
The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidificationmode'D'.
Start humidity< stop humidity, humidificationmode 'E'.
-
Dehumidificationmode:
When the humidity≥Start humidity,relay conduction, green led on, dehumidification equipment begin to work;
When the humidity≤Stophumidity,relay disconnect, green led off, dehumidificationequipment stop to work;
-
Humidificationmode:
When the humidity≤Start humidity,relay conduction, green led on, humidificationequipment begin to work;
When the humidity≥Stophumidity,relay disconnect, green led off, humidificationequipment stop to work;
-
Humidificationcorrection function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correction, the actual humidity= measuring humidity+ calibration value;
How to set the start/stop humidity:
1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humiditysettings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humiditysettings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Running Interface Description:
Working mode shows that the current mode (""H/C"", ""E/d"") will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.
Any relay conduction, the upper-left corner of the interface display ""out"", if the temperature relay conduction, the flashing display temperature working mode ""H/C"" to show reminders; if the humidity relay conduction, then flashing display humidity working mode ""E/d"", as a reminder;
Other features:
-
Parameter remote read/set:
Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;
-
temperature/Humidity Real-time reporting:
If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;