+8613432040874

Leave Your Message
Infrared carbon dioxide sensor MH-Z19B air quality monitoring/CO2 concentration detection sensor module with pins -72338
Products

Infrared carbon dioxide sensor MH-Z19B air quality monitoring/CO2 concentration detection sensor module with pins -72338

MH-Z19 Series IR Infrared CO2 Sensor Module Gas NDIR Monitor 0-5000ppm UART

    product detail

    MH-Z19E MH-Z19D, the specifications are the same, the model name is changed by the factory.


    MH-Z19B carbon dioxide gas sensor (hereinafter referred to as the sensor) is a general-purpose smart small-scale sensor that uses non-dispersive infrared (NDIR) principle to detect the presence of CO2 in the air, with good selectivity and anaerobic  Gas dependence, long life and other characteristics; built-in temperature compensation; at the same time with serial output, analog output and PWM output, easy to use. The sensor is a high-performance sensor that combines mature infrared absorption gas detection technology with precise optical path design and sophisticated circuit design.

    Parameters:

    • Product model number: MH-Z19B

    • Gas Detection: Carbon Dioxide

    • Supply voltage: 4.5~5.5V DC

    • Average current: <20mA (@5V power supply)

    • Peak current: 150 mA (@5V supply)

    • Interface level: 3.3V (5V compatible)

    • Measurement range: 0~10000ppm can be selected within the range

    • Warm-up time: 3min

    • Response time: T90<120s

    • Working temperature: 0~50°C

    • Operating Humidity: 0 to 95% RH (non-condensing)


    Characteristics:

    • Gas chamber with gold plating, waterproof and corrosion resistant

    • High sensitivity, low power consumption

    • Excellent stability

    • Temperature compensation, excellent linear output

    • Provides serial (UART), analog (DAC), PWM waveform output methods

    • long lasting

    • Water vapor interference, not poisoning



    Application:

    • HVAC refrigeration equipment

    • Air quality monitoring equipment

    • Fresh air system

    • Air purification equipment

    • Smart home

    • SCHOOL


    Vin: Power Positive (Vin)

    GND: Negative Power Supply (GND)

    Vo: Analog output

    PWM: PWM

    HD: HD (zero for school, low for more than 7 seconds)

    Rx: UART(RXD) TTL Level Data Input

    Tx: UART (TXD) TTL level data output



    Pin 1: Analog Output Vo

    Pin 2: None

    Pin 3: Negative Power Supply (GND)

    Pin 4: Positive Power Supply (Vin)

    Pin 5: UART(RXD) TTL Level Data Input

    Pin 6: UART (TXD) TTL Level Data Output

    Pin 7: None


    The MH-Z19C carbon dioxide gas sensor (hereinafter referred to as the sensor) is a general-purpose intelligent small sensor that uses the principle of non-dispersive infrared (NDIR) to detect the presence of C02 in the air. And other features; built-in temperature compensation: simultaneously has serial output, PWM output, easy to use. The sensor is a high-performance sensor made by closely combining mature infrared absorption gas detection technology with sophisticated optical circuit design and sophisticated circuit design.
    Product parameters:
    Detection gas: carbon dioxide
    Power supply voltage: DC (5.0 ± 0.1) V
    Average current: <40mA (@5V power supply)
    Peak current: 125 to (@5V power supply)
    Interface level: 3. 3v (compatible with 5v)
    Measuring range: 400-5000PPM optional
    Output signal: serial UART (TL level 3.3V)
    Warm-up time: 1min
    Response time: T90< 120s
    Working temperature: -10-50degree
    Working humidity: 0~95%RH (no condensation)
    Pin description:
    Vin: Power +(in)
    GND: power supply-(GND)
    PWM: PWM
    Hd: HD (zero calibration, low level is effective for more than 7 seconds)
    Rx: UART (RXD) TTL level data input
    Tx: UART (TXD) TTL level data output
    Output method:
    PWM output
    Assume the measurement range is 400-2000ppm
    CO2: Concentration output range: 400-2000ppm
    Period: 1004ms±5%
    High level output at the beginning of the cycle: 2ms (theoretical value)
    Central period: 1000ms±5%
    Low level output at the end of the period: 2ms (theoretical value)
    Calculation formula for obtaining current CO2 concentration value by PWM: Cppm=2000X (TH-2ms)/(TH+TL-4ms)
    Cppm: CO2 concentration value calculated by the unit of ppm
    TH: the time when the output is high level in one output cycle
    TL: the time when the output is low in one output cycle