    Product parameters:
    The greater the pressure, the lower the resistance
    4mm small range: 50g-2kg
    4mm mid-range: 1kg-15kg
    4mm large range: 2.5kg-35kg
    5mm: 5g-600g
    7mm: 30g-1.5kg
    18mm: 20g-6kg
    110mm: 20g-≥10kg
    Pin description:
    VCC: positive supply voltage (5V)
    GND: negative supply voltage
    DO: High point level signal output
    AO: analog voltage signal output (0-3.3V)
    AO-RES: magnification adjustment potentiometer
    DO-RES: comparison threshold adjustment potentiometer
    Instructions for use:
    Gasket installation
    Place the green surface of the gasket on the sensor, in the center of the sensor sensing area, and then apply the tested object vertically to the gasket, so that the effective contact and force of the sensor and the tested object all act on the sensor sensing area.
    Precautions when installing and using the sensor
    1. Try to choose a stable, smooth and flat installation surface;
    When your mounting surface is curved, you must bend it when you install the sensor, so that-the sensor sensing area will be stressed, which will affect the accuracy of the sensor to a certain extent, so be careful not to make the sensor effective The surface is installed on a curved surface with a large curvature (Note: the round effective surface cannot be bent, and the long tail can be bent);
    2. It is recommended to use a flexible gasket with a relatively stable elasticity between the sensor and the measured object to ensure effective contact between the sensor and the measured object;
    3. Keep the contact surface of the sensing area clean;
    4. The force should not exceed its rated range;
    5. Try not to solder it directly to the universal board or the circuit board without the specific package belonging to it, so as to avoid the thermal deformation of the tail and poor contact. The metal terminal of the sensor can be connected to the wire by fast welding.