HDC1080 CCS811 CO2/VOCs/Air Quality Temp/Humidity Sensor Module

    product detail


    Characteristic:

           This module integrates two sensor chips CCS811 and HDC1080 on one board. The measured values of the two sensors can be read separately by IIC communication. The HDC1080 is a low power, high precision, miniature digital temperature and humidity sensor chip.

           The CCS811 is a low-power miniature gas digital sensor for air quality monitoring. A metal oxide (MOX) sensor is integrated to measure the total equivalent volatile organic compound eTVOCs and equivalent eCO2 content. A microcontroller MCU is integrated inside the chip. The gas content value measured by CCS81 is self-corrected by reading the temperature and humidity value of the HDC1080 sensor and writing it to the CCS811 internal environment temperature and humidity correction register.

    HDC1080 parameters:
    • Working temperature: -20 ° C ~ 70 ° C

    • Humidity sensor measurement range: 0 ~ 100% RH

    • Humidity sensor accuracy: 14 bits error ± 2% RH

    • Humidity repeatability accuracy: ±0.1% RH

    • Humidity sensor response time: 15s

    • Humidity conversion time: 8 bits 2.5ms, 11 bits 3.85ms, 14 bits 6.5ms

    • Temperature sensor error: ±0.4 °C (ambient temperature 5 ° C ~ 60 ° C)

    • Temperature repeatability accuracy: ±0.1 °C

    • Temperature conversion time: 11 digits 3.85ms, 14 digits 6.5ms

    • IIC communication frequency: 400KHz

    • IIC slave address: 1000000x (x read/write control bit)

    • Power supply: recommended 3.3V

     
    CCS811 parameters:
    • Power supply: recommended 3.3V

    • Power consumption: up to 60mW

    • IIC communication frequency: 400KHz

    • eTVOC detection range: 0 ~ 32768ppb

    • eCO2 detection range: 400 ~ 32768ppm

    • Automatic baseline correction time for metal oxide sensitive layer: 24H

    • Allow configuration and read sensor time after power up: at least 20 minutes

     
    Instructions for use:
    • ADD: CCS811 slave address selection bit, the default is connected to low level 1011010x, connected to high level 1011011x (x bit read and write control bit)

    • RST: CCS811 reset control terminal, active low, not connected to high level when not in use, do not hang

    • INT: CCS811 measurement end or over-threshold interrupt source output low level

    • WAK: CCS811 wake-up control input, active low

    • SDA: CCS811 and HDC1080 common IIC data signal lines

    • SCL: CCS811 and HDC1080 common IIC clock signal lines

    • VCC: CCS811 and HDC1080 common power supply terminal